217-01-36R38W | 36-Row Wired On-Site FMS+ Kit

SKU: 217-01-36R38W

This is the COMPLETE system kit for a 36 row planter applying product at a high application rate. (minimum 13 GPA at 5 MPH)

The OnSite FMS+ 36-Row FlowBoard Kit comes complete with everything you need to monitor the liquid on your planter or strip till. This kit contains the assembled FlowBoards, The monitor kit, OnSite FMS+ modules, flowmeters, wiring harnesses, mounting brackets, and all mounting hardware. If you are adding liquid to a planter for the first time, give us a call for all the tanks, pumps, hoses, drop tubes, and everything else you need for your specific model of planter.

This FlowBoard features 3/8″ high-flow flowmeters.
This board is designed for products that need a fairly high application rate. Most in-furrow applications will be better served by using our standard 1/4″ flowmeters due to their performance at lower flow rates.

· Each 3/8″ high-flow flowmeter has a flow rate between 0.21 – 2.0 GPM per row. (8.316 GPA – 79.2 GPA at 5MPH and 30″ spacing)
· 1/4″ standard flowmeter boards are available (217-01-36r25w) and have a flow rate of 0.08 – 0.5 GPM per row. (3.168 GPA – 19.8 GPA at 5 MPH and 30″ spacing)

Choose the flowmeter that best fits your desired application rate & speed. Use the formulas below to figure out the right size for you.

Calculating gallons per acre from gallons per minute (and vice versa).

GPA = (GPM x 5,940) / (MPH x W)
GPM = (GPA x MPH x W) / (5,940)

· GPA = Gallons Per Acre
· GPM = Gallons Per Minute
· 5,940 = Constant for this Formula
· MPH = Speed You Will Be Traveling
· W = Nozzle Spacing in Inches

The big 7″ touchscreen display is the real brains of the OnSite FMS+ system. It takes the flow meter readings compiled by the OnSite Modules and converts the data to an easy-to-understand bar graph that gives you real-time monitoring of how each row is performing. You will see at a glance how each row is performing and see trends (otherwise known as blockages) as they develop.

Set your target application rates in the OnSite software and it will give you a reference line right on the display so you can see exactly how accurately each row is performing. If OnSite detects any row falling out of the acceptable range, it will change the color of the row and give you an alert. (Alerts can also be silenced.)
If you are running section control, just map the sections to your rows using the easy-to-use section wizard in the software. OnSite Smart Sense will automatically detect when sections are shut off and not trigger alerts.
Software Setup is easy. OnSite Smart Sense will automatically connect to all the OnSite Modules on the planter and put them in the right order. Configuration is largely automated. Just make a few quick choices to tell the software how you want to run. Most OnSiteFMS+ systems can be configured and ready to plant in under 15 minutes.

The OnSite Harness Terminator
The OnSite Terminator tells the system that there are no more modules to connect to. The first OnSite Module connects to the Module Power Cable and the last OnSite Module gets the terminator on the end. Everything in the middle connects with Module-to-Module cables. The whole system is wired in a simple daisy chain configuration, leaving little possibility of hooking anything up wrong.

The terminator comes with a jumper plug already installed. If you would like to use a lift switch, unplug the jumper and plug the lift switch into that port. BENCO has push button lift switch kits available with brackets designed to fit almost any planter on the market.

Kit Includes:
Three 12-row FlowBoards
Three OnSite FMS+ Modules
Thirty-six 3/8″ flowmeters mounted to the three FlowBoards
A single section, 12-row manifold with 1″ Female Pipe Thread inlet on each FlowBoard
FlowBoards come plumbed from the manifold to the flowmeters.
One Display kit
– 7″ touchscreen monitor
– Monitor cradle
– RAM Mount with extension arm
OnSite terminator plug
One 20′ Cradle-to-Hitch harness with power extension
One 50′ Hitch to Module harness
Three OnSite Module harness
Two Module-to-Module harnesses
Three FlowBoard stands with U-brackets and hardware
All necessary brackets, hardware and wiring

Does not include: Tanks, pumps, hoses, or fittings going into or out of the FlowBoard.
This kit comes with everything you need to update a planter that has liquid already on it (particularly an old red ball setup) to OnSite FMS. It does not include tanks, pumps, hose or fittings either into the FlowBoard or out of the FlowBoard to the row units. If you are installing liquid on a planter for the first time, all of these products are available from BENCO, but not included with the OnSite FMS+ kit due to the variations between machines. Call 605-213-1010 and we will develop a full liquid handling solution for your planter or strip till.

$7,640.00

FAQ

A detailed answer to provide information about your business, build trust with potential customers, or help the visitor with a problem they may be encountering

A detailed answer to provide information about your business, build trust with potential customers, or help the visitor with a problem they may be encountering

A detailed answer to provide information about your business, build trust with potential customers, or help the visitor with a problem they may be encountering

A detailed answer to provide information about your business, build trust with potential customers, or help the visitor with a problem they may be encountering

A detailed answer to provide information about your business, build trust with potential customers, or help the visitor with a problem they may be encountering

A detailed answer to provide information about your business, build trust with potential customers, or help the visitor with a problem they may be encountering

A detailed answer to provide information about your business, build trust with potential customers, or help the visitor with a problem they may be encountering

A detailed answer to provide information about your business, build trust with potential customers, or help the visitor with a problem they may be encountering

Customer Reviews

“A review from a customer who benefited from your product. Reviews can be a highly effective way of establishing credibility and increasing your company's reputation.”
Customer Name
“A review from a customer who benefited from your product. Reviews can be a highly effective way of establishing credibility and increasing your company's reputation.”
Customer Name
“A review from a customer who benefited from your product. Reviews can be a highly effective way of establishing credibility and increasing your company's reputation.”
Customer Name